游艇会0088yth

    Product

    Product

    Smart High Side Switch

    The NSE34xxx/NSE35xxx series high-side switches are designed for driving various traditional resistive, inductive, and halogen lamp loads in systems like automotive BCMs, while also being well-suited for handling large capacitive loads commonly found in first and second-level distribution in Zonal Control Units (ZCUs). These series offer options for 1, 2, or 4 channels and are available in HSSOP-16/HSSOP-14 packages, with an Rds(on) range from 8mΩ to 140mΩ. The chips feature precise current sensing, ideal for fault diagnosis, protection, and real-time monitoring of load currents. Additionally, the NSE34xxx/NSE35xxx series incorporate comprehensive protection mechanisms, including overcurrent/short-circuit protection, overtemperature protection, overvoltage protection, ground and power loss protection, reverse polarity protection, and open-load detection.The NSE34xxx and NSE35xxx series products are AEC-Q100 qualified and certified to AEC-Q100-012 level A, ensuring over a million cycles of short-circuit and overcurrent protection.

    View All Products

    • Ambient Temperature
      -40°C~125°C
    • Number of Channels
      1CH
      2CH
      4CH
    • MOS Impedance
      8mΩ
      10mΩ
      12mΩ
      25mΩ
      50mΩ
      140mΩ
    • Package
      HSSOP-16
      HSSOP-14

    show 27 devices

    Part Number ECAD Model Ambient Temperature Number of Channels MOS Impedance Protection Feature Application Package
    NSE34025Q
    -40℃~125℃
    4CH
    25mΩ
    Overcurrent protection
    Short-circuit protection
    Overvoltage protection
    Over-temperature protection
    Lost ground protection
    Lost power protection
    Reverse polarity protection
    Open circuit diagnosis
    Support inductive loads
    BCM
    ZCU
    HSSOP-16
    NSE34050Q
    -40℃~125℃
    4CH
    50mΩ
    Overcurrent protection
    Short-circuit protection
    Overvoltage protection
    Over-temperature protection
    Lost ground protection
    Lost power protection
    Reverse polarity protection
    Open circuit diagnosis
    Support inductive loads
    BCM
    ZCU
    HSSOP-16
    NSE34140Q
    -40℃~125℃
    4CH
    140mΩ
    Overcurrent protection
    Short-circuit protection
    Overvoltage protection
    Over-temperature protection
    Lost ground protection
    Lost power protection
    Reverse polarity protection
    Open circuit diagnosis
    Support inductive loads
    BCM
    ZCU
    HSSOP-16
    NSE34050D
    -40℃~125℃
    2CH
    50mΩ
    Overcurrent protection
    Short-circuit protection
    Overvoltage protection
    Over-temperature protection
    Lost ground protection
    Lost power protection
    Reverse polarity protection
    Open circuit diagnosis
    Support inductive loads
    BCM
    ZCU
    HSSOP-16
    NSE34050S
    -40℃~125℃
    1CH
    50mΩ
    Overcurrent protection
    Short-circuit protection
    Overvoltage protection
    Over-temperature protection
    Lost ground protection
    Lost power protection
    Reverse polarity protection
    Open circuit diagnosis
    Support inductive loads
    BCM
    ZCU
    HSSOP-16
    NSE34140D
    -40℃~125℃
    2CH
    140mΩ
    Overcurrent protection
    Short-circuit protection
    Overvoltage protection
    Over-temperature protection
    Lost ground protection
    Lost power protection
    Reverse polarity protection
    Open circuit diagnosis
    Support inductive loads
    BCM
    ZCU
    HSSOP-16
    NSE34140S
    -40℃~125℃
    1CH
    140mΩ
    Overcurrent protection
    Short-circuit protection
    Overvoltage protection
    Over-temperature protection
    Lost ground protection
    Lost power protection
    Reverse polarity protection
    Open circuit diagnosis
    Support inductive loads
    BCM
    ZCU
    HSSOP-16
    NSE34025D
    -40℃~125℃
    2CH
    25mΩ
    Overcurrent protection
    Short-circuit protection
    Overvoltage protection
    Over-temperature protection
    Lost ground protection
    Lost power protection
    Reverse polarity protection
    Open circuit diagnosis
    Support inductive loads
    BCM
    ZCU
    HSSOP-16
    NSE34025S
    -40℃~125℃
    1CH
    25mΩ
    Overcurrent protection
    Short-circuit protection
    Overvoltage protection
    Over-temperature protection
    Lost ground protection
    Lost power protection
    Reverse polarity protection
    Open circuit diagnosis
    Support inductive loads
    BCM
    ZCU
    HSSOP-16
    NSE34012D
    -40℃~125℃
    2CH
    12mΩ
    Overcurrent protection
    Short-circuit protection
    Overvoltage protection
    Over-temperature protection
    Lost ground protection
    Lost power protection
    Reverse polarity protection
    Open circuit diagnosis
    Support inductive loads
    BCM
    ZCU
    HSSOP-16
    NSE34012S
    -40℃~125℃
    1CH
    12mΩ
    Overcurrent protection
    Short-circuit protection
    Overvoltage protection
    Over-temperature protection
    Lost ground protection
    Lost power protection
    Reverse polarity protection
    Open circuit diagnosis
    Support inductive loads
    BCM
    ZCU
    HSSOP-16
    NSE34008D
    -40℃~125℃
    2CH
    8mΩ
    Overcurrent protection
    Short-circuit protection
    Overvoltage protection
    Over-temperature protection
    Lost ground protection
    Lost power protection
    Reverse polarity protection
    Open circuit diagnosis
    Support inductive loads
    BCM
    ZCU
    HSSOP-16
    NSE34008S
    -40℃~125℃
    1CH
    8mΩ
    Overcurrent protection
    Short-circuit protection
    Overvoltage protection
    Over-temperature protection
    Lost ground protection
    Lost power protection
    Reverse polarity protection
    Open circuit diagnosis
    Support inductive loads
    BCM
    ZCU
    HSSOP-16
    NSE35120DA
    -40℃~125℃
    2CH
    60mΩ
    Overcurrent protection
    Short-circuit protection
    Overvoltage protection
    Over-temperature protection
    Lost ground protection
    Lost power protection
    Reverse polarity protection
    Open circuit diagnosis
    Support inductive loads
    BCM
    ZCU
    HSSOP-14
    NSE35200DA
    -40℃~125℃
    2CH
    60mΩ
    Overcurrent protection
    Short-circuit protection
    Overvoltage protection
    Over-temperature protection
    Lost ground protection
    Lost power protection
    Reverse polarity protection
    Open circuit diagnosis
    Support inductive loads
    BCM
    ZCU
    HSSOP-14
    NSE35040DA
    -40℃~125℃
    2CH
    20mΩ
    Overcurrent protection
    Short-circuit protection
    Overvoltage protection
    Over-temperature protection
    Lost ground protection
    Lost power protection
    Reverse polarity protection
    Open circuit diagnosis
    Support inductive loads
    BCM
    ZCU
    HSSOP-14
    NSE35040SA
    -40℃~125℃
    1CH
    20mΩ
    Overcurrent protection
    Short-circuit protection
    Overvoltage protection
    Over-temperature protection
    Lost ground protection
    Lost power protection
    Reverse polarity protection
    Open circuit diagnosis
    Support inductive loads
    BCM
    ZCU
    HSSOP-14
    NSE35080DA
    -40℃~125℃
    2CH
    20mΩ
    Overcurrent protection
    Short-circuit protection
    Overvoltage protection
    Over-temperature protection
    Lost ground protection
    Lost power protection
    Reverse polarity protection
    Open circuit diagnosis
    Support inductive loads
    BCM
    ZCU
    HSSOP-14
    NSE35012DA
    -40℃~125℃
    2CH
    12mΩ
    Overcurrent protection
    Short-circuit protection
    Overvoltage protection
    Over-temperature protection
    Lost ground protection
    Lost power protection
    Reverse polarity protection
    Open circuit diagnosis
    Support inductive loads
    BCM
    ZCU
    HSSOP-14
    NSE35012SA
    -40℃~125℃
    1CH
    12mΩ
    Overcurrent protection
    Short-circuit protection
    Overvoltage protection
    Over-temperature protection
    Lost ground protection
    Lost power protection
    Reverse polarity protection
    Open circuit diagnosis
    Support inductive loads
    BCM
    ZCU
    HSSOP-14
    NSE35020DA
    -40℃~125℃
    2CH
    12mΩ
    Overcurrent protection
    Short-circuit protection
    Overvoltage protection
    Over-temperature protection
    Lost ground protection
    Lost power protection
    Reverse polarity protection
    Open circuit diagnosis
    Support inductive loads
    BCM
    ZCU
    HSSOP-14
    NSE35030DA
    -40℃~125℃
    2CH
    12mΩ
    Overcurrent protection
    Short-circuit protection
    Overvoltage protection
    Over-temperature protection
    Lost ground protection
    Lost power protection
    Reverse polarity protection
    Open circuit diagnosis
    Support inductive loads
    BCM
    ZCU
    HSSOP-14
    NSE35010DA
    -40℃~125℃
    2CH
    10mΩ
    Overcurrent protection
    Short-circuit protection
    Overvoltage protection
    Over-temperature protection
    Lost ground protection
    Lost power protection
    Reverse polarity protection
    Open circuit diagnosis
    Support inductive loads
    BCM
    ZCU
    HSSOP-14
    NSE35010SA
    -40℃~125℃
    1CH
    10mΩ
    Overcurrent protection
    Short-circuit protection
    Overvoltage protection
    Over-temperature protection
    Lost ground protection
    Lost power protection
    Reverse polarity protection
    Open circuit diagnosis
    Support inductive loads
    BCM
    ZCU
    HSSOP-14
    NSE35008DA
    -40℃~125℃
    2CH
    8mΩ
    Overcurrent protection
    Short-circuit protection
    Overvoltage protection
    Over-temperature protection
    Lost ground protection
    Lost power protection
    Reverse polarity protection
    Open circuit diagnosis
    Support inductive loads
    BCM
    ZCU
    HSSOP-14
    NSE35008SA
    -40℃~125℃
    1CH
    8mΩ
    Overcurrent protection
    Short-circuit protection
    Overvoltage protection
    Over-temperature protection
    Lost ground protection
    Lost power protection
    Reverse polarity protection
    Open circuit diagnosis
    Support inductive loads
    BCM
    ZCU
    HSSOP-14
    NSE35008SP
    -40℃~125℃
    1CH
    8mΩ
    Overcurrent protection
    Short-circuit protection
    Overvoltage protection
    Over-temperature protection
    Lost ground protection
    Lost power protection
    Reverse polarity protection
    Open circuit diagnosis
    Support inductive loads
    BCM
    ZCU
    HSSOP-14

    For more product information, please contact us.